skip to Main Content

Check-A-Pack 200 Leak & Burst Package Tester

Measurement of micro leak hole size and burst pressure seal integrity with oxygen analysis, for all flexible and semi-rigid packaging.

Request a Quote

The Check-A-Pack 202 is a benchtop model with manual sample preparation. Hole size measurement 5 to 200 microns. The instrument is controlled via a touchscreen with embedded software. Test methods can be saved for later recall, and all test results are automatically stored. The instrument has both USB and Ethernet connections for transfer of results if required.

Check-A-Pack 202 has the possibility to run up to 3 test modes in a single test method, these are Leak Testing, Burst Testing, and Oxygen O2 testing as described below:

1. Leak Testing: In this test the pack is gently inflated and checked for leaks in the range 5 to 200 microns. The test measures the air flow, and calculates the micron estimated hole size, by maintaining a set pressure for a defined time.

2. Burst Testing: In this test, the pack is inflated until it bursts in the range up to 1,000 mbar. The maximum pressure reached is recorded.

3. Oxygen (O2) Testing: In this test the instrument measures the amount of Oxygen inside the pack. This will tell you whether too much or too little nitrogen is being fed into the bagging line.

Benefits:

  • Manual sample preparation suits a wider variety of pack formats.
  • Tests a wide range of flexible and semi-flexible product packs and components including modified atmosphere packaging, food pouches, trays, pots, sachets, medical packs, pharma blisters, electronic packs, and industrial packaging.
  • Full traceability: operator, line, product, batch number, date, time

Features:

  • Touchscreen controller, with password protected test recipes.
  • Connectivity via USB and Ethernet, networking of results.
  • Automatic result database, recall, export, statistics, password protected.
  • Remote access for fault diagnoses, maintenance and supervision.
  • Pneumatic backflush eliminates blocked needles.

MODELS:
CHECK-A-PACK 200 Leak & Burst Tester
CHECK-A-PACK 600 Automatic Leak & Burst Tester
CHECK-A-PACK 202 Leak & Burst Tester with O2 analysis
CHECK-A-PACK 602 Automatic Leak & Burst Tester with O2 analysis
CHECK-A-PACK 222 Leak & Burst Tester with O2 & CO2 analysis
CHECK-A-PACK 622 Automatic Leak & Burst Tester with O2 & CO2 analysis

SPECIFICATION:

Leak & Burst:
Technology: Mass Flow & Piezoresistive sensors
Accuracy: +/- 2% full scale
Resolution: 0.1 ml/min & 0.1 mbar
Scale: 1000 ml/min & 1.5 bar
Sensitivity: 10 microns @ 20mbar & 5 microns @ 500mbar

Oxygen:
Technology: Electrochemical sensor
Accuracy: +/- 1% of reading +0.01% O2
Resolution: 0.01%
Sample Volume: Target <1% O2 : <4ml
Carbon Dixoide:
Technology: NDIR sensor
Accuracy: +/- 2% full scale
Resolution: 0.1%
Sample Volume: Target <90% CO2 : <6ml

Device (200):
Dimensions (mm): 345 (W) x 175 (D) x 165 (H)
Weight: 5kg
Results memory: Unlimited (adjustable memory size)
Ports: 1 x USB, 1 x Ethernet
Display: 8 inch touchscreen
Power: 100-230 VAC, 50-60Hz
Temperature: 0-40°C

Device (600):
Dimensions (mm): 569(W) x 473(D) x 495(H)
Weight: 25kg
Results memory: Unlimited (adjustable memory size)
Ports: 1 x USB, 1 x Ethernet
Display: 8 inch touchscreen
Power: 100-230 VAC, 50-60Hz
Temperature: 0-40°C

CAP datasheet thumbnail

DATA SHEET

RDM TEST BROCHURE

MEDESEAL BROCHURE

Back To Top