skip to Main Content

PERMATRAN-C ® 4/30

Carbon Dioxide permeation rate measurement system for films and packages.

The PERMATRAN-C 4/30 CO2 permeation analyzer can test the Carbon Dioxide Transmission Rate (CO2TR) on both films and packages from low to high barriers. It features two independent cells with interchangeable horizontal test cartridges that allow for a wide variety of sample sizes and packaging materials to be easily and accurately tested.

Request a Quote

The PERMATRAN-C 4/30 CO2 permeation analyser can test the Carbon Dioxide Transmission Rate (CO2TR) on both films and packages from low to high barriers. It features two independent cells with interchangeable horizontal test cartridges that allow for a wide variety of sample sizes and packaging materials to be easily and accurately tested.

 

High Accuracy

  • MOCON’s patented modulated infrared sensor is the only modulated sensor system on the market meeting ASTM F2476
  • Low CO2TR detection levels down to 0.5 cc/(m2 x day)
  • Fully automated temperature, flow controls simplify testing and provide unparalleled repeatability

High Throughput

  • Modulated IR sensors measure CO2 gas concentrations in real time greatly reducing overall CO2TR test times compared to Zahm-Nagel CO2 testing methods
  • Excellent correlation to Zahm-Nagel shelf life studies allowing equivalency while significantly reducing long term testing
  • Automated test methods can start a test by a single press of a button
  • TruSeal gas flushed perimeter sealing can eliminate the need for absolute zero in many tests, thus shortening overall test times

The PERMATRAN-C 4/30 analysers can test the Carbon Dioxide Transmission Rate (CO2TR) from low to high barriers on films, packages and bottles. Unlike manometric or Zahm-Nagel methods that require long periods of time to provide results the PERMATRAN-C 4/30 utilizes MOCON’s patented modulated IR sensor system allowing it to provide accurate results in much less time.

Designed for a wide range of barriers, this analyser provides highly repeatable test results from 0.5 to 8,000 cc/ (m2 day).  The upper detection limit can be extended with the use of a reduced area film test cartridge (factor x9), or by using various sizes of masking.

 

The analyser has industry leading features such as removable and interchangeable horizontal test cartridges, easy to use touch screen operator interface, and fully automated testing providing higher throughput in the lab with less training.

 

For more than 25 years, MOCON’s PERMATRAN series of analysers have been the most trusted and longest lasting on the market. The 4/30 delivers fast CO2TR results in less time than traditional methods helping to speed up your research and development of new materials or give you efficient QC verification of existing products.

Removable Cartridges

  • Easy sample preparation on the benchtop
  • More consistent film loading into the analyser
  • One button release and loading
  • Pneumatic clamping provides more repeatable results
  • Interchangeable cartridge options that expand the testing capability

TruSeal®

  • Eliminates Individual Zero
  • Reduces testing time (increases throughput)
  • More repeatable results

Automated Control Features

  • Flow, Temp control
  • Test Process Development and Recommendations
  • Programmable Test Sequencing
  • Test report printing and export
  • Sensor Protection

Touchscreen Interface

  • Intuitive automated operation requires less training
  • Built in multi-level user management and data security
  • Event log & trouble shooting guide
  • Save on valuable lab space by eliminating need for PC

Modulated IR Sensor

  • Short exam times reduces overall test time to increase throughput
  • Long sensor life
  • Accurate and repeatable results
  • Most trusted modulated IR sensor that fully complies with ASTM F2476

Warranty

  • Full 100% parts and workmanship warranty for 12 months
  • Exclusive 4-year warranty on the Modulated IR sensor

Capabilities – Model Specific

Units Model 4/30 L
Test Ranges (50 cm2) cc/(m2 × day) 0.5 to 8,000
cc/(100 in2 × day) 0.03 to 516
Test Ranges (5.6 cm2) cc/(m2 × day) 4.5 to 71,000
cc/(100 in2 × day) 0.29 to 4,600
Test Ranges (5.0 cm2 masked) cc/(m2 × day) 5 to 80,000
Resolution (50cm2 cc/(m2 × day) 0.0001
Test Range – Package cc/(pkg × day) 0.0025 to 40
Repeatability cc/(m2 × day) 0.25 or 2.0%*
Temperature Control Range °C 10 to 40 ± 0.2
 Humidity (RH) Control Range
Film Cell, Test Gas
 % RH  Dry Only

*Whichever is larger

Capabilities

PERMATRAN-C 4/30 Units
Film Size 4” x 4” Std, 2” x 2” optional
Film Thickness Up to 120 Mil
Film Test Area 50 cmstandard cartridge
5.6 cmcartridge – optional

Other Specifications (all models):

Physical Specifications

  • 15.5” H x 12” W x 23” D (39.4 cm x 30.4 cm x 58.0 cm)
  • 95 Lbs. (43.1 kg)

Electrical Requirements

  • Voltage: 100 – 240 VAC 50/60 Hz
  • Maximum Power Draw: 700 VA

Laboratory Requirements

Temperature Operation 22 °C ± 2 °C
Storage 10 °C to 30 °C
Humidity Operation 20% to 80% RH (non-condensing)
Storage 5% to 85% RH (non-condensing)

Gas Supply Requirements

Carrier Gas Gas Composition Nitrogen (99.7% N2 or better)
Test Gas Gas Composition Carbon Dioxide (99.7% or better)

Connectivity

  • Remote Access and Control (requires optional Perm-Net Light software)
  • Standard Ethernet port (100T)
  • Dual USB 2.0 ports (for connection of keyboard, mouse or memory devices)

Compliance Standards

This product is UL and CSA listed using the ETL mark from Intertek Group plc. and is certified to conform to CE.
Conforms to the following internationally recognized safety standards.

  • IEC 61010-1:2010 Third Edition
  • UL 61010-1:2012 Third Edition
  • CAN/CSA-C22.2 No. 61010-1:2012 Third Edition

Conforms to the following internationally recognized EMC standards.

  • EN 61326-1:2013
  • EN 61000-3-2:2006, A1:2009, A2:2009
  • EN 61000-3-3:2013

Conforms to EU Directive 2011/65/EU RoHS Compliance.

Cartridges & Options

  • Reduced area cartridge
  • Blister cartridge
  • Package testing adaptor
  • PackRack package test fixture
  • Closure test cell
  • 1 Liter bottle capture volume test cell
  • 2 Liter bottle capture volume test cell

Consumables

  • Reference Films
  • Masks

Software

  • PermWare data collection, data management and instrument status dashboard
  • Remote viewing software from a PC – PermNet Lite
  • 21 CFR Part 11 user and data security

Service & Support Options

  • IQ/OQ documentation & validation
  • Basic Preventative Maintenance Plan
  • Plus Preventative Maintenance Plan

Packaging Films

  • Monolayer
  • Multi-layer
  • Coated Films

Packages

  • Common food packages
  • Bottles/Closures

Test Standard Compliance

  • ASTM F2476
  • DIN 53380-4
  • ISO 15105-2

Test Methodology

Following ASTM F2476-13;

Standard Test Method for the Determination of Carbon Dioxide Gas Transmission Rate (CO2TR) Through Barrier Materials Using an Infrared Detector

Summary of Test Method:

1. The carbon dioxide gas transmission rate is determined after the sample has equilibrated in a dry-test environment. In this context, a “dry” environment is considered to be one in which the relative humidity is less than 1 %.
2. The specimen is mounted as a sealed semi-barrier between two chambers at ambient atmospheric pressure. One chamber is slowly purged by a stream of nitrogen and the other chamber with carbon dioxide. As carbon dioxide gas permeates through the film into the nitrogen carrier gas, it is transported to an infrared detector where an electrical output is produced whose magnitude is proportional to the amount of CO2 flowing into the detector per unit of time.

permatran 430

DATA SHEET

RDM TEST BROCHURE

MEDESEAL BROCHURE

Back To Top